Commercial Kitchen Grease Trap Sizing & Plumbing Code Compliance in Texas

Sizing indoor hydromechanical grease interceptors (HGI) vs. exterior gravity interceptors (GGI). Texas Commission on Environmental Quality (TCEQ) rules and municipal pumping schedules.

Grease interceptor compliance is strictly enforced by municipal utility districts and health inspectors across Texas. Improper sizing delays certificate of occupancy permits.

Key Sizing Calculations

Engineers calculate fixture unit (DFU) loading and peak gallon flow rates from 3-compartment pot sinks, prep sinks, floor drains, and mop basins to select certified PDI G-101 interceptor units.

Frequently Asked Questions

What size grease trap does a Texas restaurant require?

Full-service restaurants with commercial fryers and dishwashers typically require a 1,000 to 1,500-gallon exterior precast concrete gravity interceptor. Small cafes or bakeries may be permitted with point-of-use 50 to 100 GPM indoor hydromechanical units.

How often must grease traps be pumped in Texas?

Under the Texas "25% Rule", interceptors must be pumped out completely whenever the total depth of floating fats, oils, grease, and settled solids exceeds 25% of the liquid depth, or at least every 90 days.

Can dishwashers discharge into indoor grease traps?

No. High-temperature commercial dishwasher discharge (140°F+) melts grease, allowing it to bypass indoor point-of-use traps and congeal further down the line. Dishwasher lines must route to exterior gravity interceptors.